These are real inspections conducted by Cleanaholics Malaysia across the Klang Valley between April and May 2026. All client names and exact addresses have been removed for confidentiality. Property type, neighbourhood, square footage, inspection findings, and remediation outcomes are real and unaltered.
Inspector: Mr. Vin, Senior Hygiene Inspector · Equipment: HIKMICRO Thermal Camera, Protimeter Surveymaster, 6-in-1 Air Quality Monitor
A multi-storey terrace villa within KLGCC East Residence in Bukit Kiara — the premium golf-club residential enclave adjacent to the Kuala Lumpur Golf & Country Club. The lower-ground level serves as the grand entrance with vehicle parking; living areas open directly off this entrance level. Architectural risk identified: living-area shoe-rack and entrance zones inherit garage-level humidity, vehicle-borne moisture (rain, wet shoes), and reduced cross-ventilation. Hidden mould at the entrance shoe-rack was diagnosed as a structural-design risk inherent to this build — not a housekeeping failure. This pattern is common across multi-storey KLGCC East Residence villas.
Master Bedroom Suite, Bedrooms 2–5, Living Room (entrance level), Dining Area (1st Floor), Kitchen, three full bathrooms, Guest Toilet (ground floor), Middle Toilet (2nd Floor), Master Ensuite (2nd Floor), Music Room (2nd Floor), Shoe Cabinet (interior), Staircase / Common.
Mixed indoor-environment profile: several rooms in good health (master bedroom suite, kitchen, top floor); three rooms (1st-floor toilet, 1st-floor dining area, 2nd-floor middle toilet) require structural remediation, not surface hygiene science. Recommended protocol: HEPA-13 containment, substrate extraction of contaminated MDF cabinet doors and ceiling gypsum, photocatalytic anti-microbial coating, post-treatment independent laboratory verification.
Written diagnostic report delivered to homeowner within 48 hours of inspection. Customised remediation quotation included. Inspection fee fully credited toward subsequent remediation project.
Inspector: Mr. Vin, Senior Hygiene Inspector · Homeowner reference: Ms. T (Australian expatriate family)
Premium high-rise condominium in Mont Kiara, Kuala Lumpur. International family relocated from Sydney 18 months prior. Master ensuite bathroom developed black staining on the gypsum ceiling near the split-system AC unit. Homeowner had attempted bleach treatment twice over 18 months; mould returned within 6–10 weeks each time — a common pattern in Mont Kiara high-rise condominium ensuites where AC drip-pans overflow during humidity spikes.
Inspector: Mr. Vin, Senior Hygiene Inspector · Engagement: Multinational business-services firm
A multinational business-services corporation operating in Selangor required an indoor air quality compliance audit ahead of an internal occupational-health review. The 13-point hygiene science methodology was applied to all occupied zones. This is the standard format Cleanaholics delivers for corporate clients requiring DOSH ICOP IAQ 2010 compliance documentation.
Inspector: Mr. Vin, Senior Hygiene Inspector · Homeowner reference: Mr. A (young Malaysian family)
Newly renovated family home in Rawang, Selangor. Young Malaysian family moved in 3 weeks post-renovation; mother reported persistent headaches, child developed nighttime cough. Classic post-renovation MDF off-gassing pattern increasingly common across newer Rawang and Selangor developments.
Every Cleanaholics hygiene & mould inspection follows the same 13-point methodology demonstrated in these case studies, conducted on-site by Mr. Vin (Senior Hygiene Inspector) using calibrated HIKMICRO thermal imaging, Protimeter Surveymaster moisture metering, and professional 6-in-1 air quality monitoring.